Residual current monitors (Residual-current device) HYCA-F10 type
Residual current monitors model HYCA-F10 is a specialized leakage current sensor designed for wall-mounted electric vehicle (EV) charging stations. This sensor is engineered to ensure the safety and reliability of the EV charging process. HYCA-F10 employs advanced technology for precise leakage current detection and offers various customization options to meet the specific needs of different customers.
| Model | Corresponding standards | DC trigger threshold | AC trigger threshold |
| HYCA-10/MD | IEC62955 | 6mA | / |
| Absolute maximum ratings (not operating) | ||||
| Electrical data | Symbol | Unit | Specification | Conditions |
| Load dump vervoltage | UC | V | 32 | 400ms |
| Over-voltage | UC | V | 25 | 1 minute |
| Reverse polarity | UC | V | -16 | 1 minute |
| Minimum supply voltage | UCmin | V | 6 | Continuous not operating |
| Maximum supply voltage | UCmax | V | 18 | Continuous not operating← |
| Creepage distance | dcp | mm | 7.2 | |
| Clearance | dci | mm | 6.9 | |
| RMS voltage for AC insulation test | Ud | KV | 2.5 | 50HZ, 1minute |
| Insulation resistance | Rins | MΩ | 500 | 500 V iso 16750-2 |
|
Electrical data – Ratings: |
||||
|
Action current |
Unit | Min. | Typ | Max. |
|
Operating current S-DC |
mA | 3 | 4.6 | 6 |
|
Operating current 2PDC |
mA | 3.5 | 4.6 | 7 |
|
Operating current 3PDC |
mA | 3.1 | 4.6 | 6.2 |
|
|
||||
|
Operating time |
Unit | Min | Typ | Max |
| Limit values of break time@6mA DC | ms | 100 | 10000 | |
|
Limit values of break time@60mA DC |
ms |
50 | 300 | |
|
Limit values of break time@200mA DC |
ms |
50 | 100 | |
| Limit values of break time@60mA 2PDC | ms |
50 | 300 | |
| Limit values of break time@200mA 2PDC | ms |
50 | 100 | |
| Limit values of break time@60mA 3PDC | ms |
50 | 300 | |
| Limit values of break time@200mA 3PDC | ms |
50 | 100 | |
| No action time | Unit | Min | Typ | LOWER |
| Limit values of break time@30mA AC | ms |
∞ |
∞ | |
| Limit values of break time@60mA AC | ms |
∞ |
300 | |
| Limit values of break time@150mA AC | ms |
∞ |
80 | |
| Limit values of break time@5A AC | ms |
>80 |
80 |
|
Dimensions
| Mechanical dimension(for reference only) |
![]() |
Standards
1. Is HYCA-10/MD designed for wall-mounted EV chargers?
The HYCA-10 family is presented for wall-mounted EV charging equipment. HYCA-10/MD can be evaluated where a 6 mA DC monitoring function is required. Check the controller interface, conductor opening and protection arrangement for the particular wallbox.
2. Does HYCA-10/MD provide a 30 mA AC protective threshold?
The HYCA-10/MD model table lists a 6 mA DC threshold without a separate AC threshold. If your charger requires 30 mA AC protection, it must be provided by the appropriate overall protection arrangement or a suitable sensor variant.
3. How does HYCA-10/MD compare with HYCA-10/PD?
HYCA-10/MD is the listed 6 mA DC monitoring version. HYCA-10/PD additionally lists a 30 mA AC threshold. Consider the complete RDC-DD design, connector interface, control logic and available installation space before choosing.
4. Can HYCA-10/MD be customized for an OEM charger?
The HYCA-10 product description mentions customization, including design and mechanical requirements. Send the required sensor opening, housing constraints, connector details and projected volume so HEYI can assess technical feasibility and commercial terms.
5. What data should a manufacturer request before testing HYCA-10/MD?
Request the correct HYCA-10/MD datasheet revision, normal supply requirements, connection diagram, DC trigger characteristics and response-time conditions. Validate the sensor and finished charging system separately during design qualification.