Residual current monitors (Residual-current device) HYCA-F10 type
Residual current monitors model HYCA-F10 is a specialized leakage current sensor designed for wall-mounted electric vehicle (EV) charging stations. This sensor is engineered to ensure the safety and reliability of the EV charging process. HYCA-F10 employs advanced technology for precise leakage current detection and offers various customization options to meet the specific needs of different customers.
| Model | Corresponding standards | DC trigger threshold | AC trigger threshold |
| HYCA-10/MD | IEC62955 | 6mA | / |
| Absolute maximum ratings (not operating) | ||||
| Electrical data | Symbol | Unit | Specification | Conditions |
| Load dump vervoltage | UC | V | 32 | 400ms |
| Over-voltage | UC | V | 25 | 1 minute |
| Reverse polarity | UC | V | -16 | 1 minute |
| Minimum supply voltage | UCmin | V | 6 | Continuous not operating |
| Maximum supply voltage | UCmax | V | 18 | Continuous not operating← |
| Creepage distance | dcp | mm | 7.2 | |
| Clearance | dci | mm | 6.9 | |
| RMS voltage for AC insulation test | Ud | KV | 2.5 | 50HZ, 1minute |
| Insulation resistance | Rins | MΩ | 500 | 500 V iso 16750-2 |
|
Electrical data – Ratings: |
||||
|
Action current |
Unit | Min. | Typ | Max. |
|
Operating current S-DC |
mA | 3 | 4.6 | 6 |
|
Operating current 2PDC |
mA | 3.5 | 4.6 | 7 |
|
Operating current 3PDC |
mA | 3.1 | 4.6 | 6.2 |
|
|
||||
|
Operating time |
Unit | Min | Typ | Max |
| Limit values of break time@6mA DC | ms | 100 | 10000 | |
|
Limit values of break time@60mA DC |
ms |
50 | 300 | |
|
Limit values of break time@200mA DC |
ms |
50 | 100 | |
| Limit values of break time@60mA 2PDC | ms |
50 | 300 | |
| Limit values of break time@200mA 2PDC | ms |
50 | 100 | |
| Limit values of break time@60mA 3PDC | ms |
50 | 300 | |
| Limit values of break time@200mA 3PDC | ms |
50 | 100 | |
| No action time | Unit | Min | Typ | LOWER |
| Limit values of break time@30mA AC | ms |
∞ |
∞ | |
| Limit values of break time@60mA AC | ms |
∞ |
300 | |
| Limit values of break time@150mA AC | ms |
∞ |
80 | |
| Limit values of break time@5A AC | ms |
>80 |
80 |
|
Dimensions
| Mechanical dimension(for reference only) |
![]() |
Standards


Tel:13968747975
E-mail: bethy@heyiele.com
Add:(Zhejiang Lierde Relay Co., Ltd.) Xinguang Ind. Zone, Liushi Town, Wenzhou, Zhejiang, China