Residual current monitors (Residual-current device) HYCA-F10 type
Residual current monitors model HYCA-F10 is a specialized leakage current sensor designed for wall-mounted electric vehicle (EV) charging stations. This sensor is engineered to ensure the safety and reliability of the EV charging process. HYCA-F10 employs advanced technology for precise leakage current detection and offers various customization options to meet the specific needs of different customers.
| Model | Corresponding standards | DC trigger threshold | AC trigger threshold |
| HYCA-10/PD | IEC62955 | 6mA | 30mA |
| Absolute maximum ratings (not operating) | ||||
| Electrical data | Symbol | Unit | Specification | Conditions |
| Load dump vervoltage | UC | V | 32 | 400ms |
| Over-voltage | UC | V | 25 | 1 minute |
| Reverse polarity | UC | V | -16 | 1 minute |
| Minimum supply voltage | UCmin | V | 6 | Continuous not operating |
| Maximum supply voltage | UCmax | V | 18 | Continuous not operating← |
| Creepage distance | dcp | mm | 7.2 | |
| Clearance | dci | mm | 6.9 | |
| RMS voltage for AC insulation test | Ud | KV | 2.5 | 50HZ, 1minute |
| Insulation resistance | Rins | MΩ | 500 | 500 V iso 16750-2 |
|
Electrical data – Ratings: |
||||
|
Action current |
Unit | Min. | Typ | Max. |
|
Operating current AC |
mA | 20 | 22.8 | 26 |
|
Operating current A0 |
mA | 11 | 15 | 30 |
|
Operating current A90 |
mA | 10 | 18 | 30 |
|
Operating current A135 |
mA |
10 | 24 | 35 |
|
Operating current 2PDC |
mA |
3.5 | 5 | 7 |
|
Operating current 3PDC |
mA |
3.1 | 4.6 | 6.2 |
|
Operating current S-DC |
mA | 3 | 4.6 | 6 |
|
Operating current F |
mA |
18 | 24 | 38 |
|
|
||||
|
Wav |
Fre.q | Unit | Current | Typ |
| AC | 50HZ | ms | 30mA | 60 |
|
AC |
50HZ |
ms | 60mA | 30 |
|
AC |
50HZ |
ms | 150mA | 15 |
| AC | 50HZ |
ms | 5A-100A | 15 |
| A0 | 50HZ |
ms | 42mA | 38 |
| A0 | 50HZ |
ms | 84mA | 30 |
| A0 | 50HZ |
ms | 210mA | 25 |
| A0 | 50HZ | ms | 42mA+6mADC | 38 |
| A0 | 50HZ |
ms | 84mA+6mADC | 30 |
| A0 | 50HZ |
ms | 210mA+6mADC | 25 |
| S-DC | - |
ms | 6mA | 120 |
| S-DC | - |
ms | 60mA | 25 |
| S-DC | - |
ms | 300mA | 25 |
| 2PDC/3PDC | 50HZ |
ms | 60mA | 25 |
| 2PDC/3PDC | 50HZ |
ms | 120mA | 20 |
| 2PDC/3PDC | 50HZ |
ms | 300mA | 20 |
| 2PDC/3PDC | 50HZ | ms | 5A-50A | 15 |
| F | - | ms | 210mA | 15 |
Dimensions
| Mechanical dimension(for reference only) |
![]() |
Standards
1. What fault-current thresholds does HYCA-10/PD support?
The HYCA-10/PD technical table lists a 6 mA DC trigger threshold and a 30 mA AC trigger threshold. The published operating current depends on the waveform, so use the full datasheet when designing the fault-response logic.
2. Can HYCA-10/PD be used in a Mode 3 AC charging wallbox?
The HYCA-10 family is described for wall-mounted chargers, and HYCA-10/PD can be evaluated for Mode 3 designs. Final conformity depends on the complete charging equipment, protection switching and test evidence—not solely on the sensor specification.
3. What is the benefit of choosing HYCA-10/PD over HYCA-10/MD?
The PD variant lists both AC and DC residual-current thresholds, while the MD variant lists the DC monitoring threshold. The right choice depends on whether your charging equipment has an independent AC residual-current protective device.
4. Does HYCA-10/PD have published response times for different leakage waveforms?
Yes. The product page provides typical times for sinusoidal AC, pulsating DC, smooth DC and other test waveforms. Use the specific test current and waveform from the table and independently verify total disconnection time in the finished charger.
5. Can HEYI adapt HYCA-10/PD dimensions or branding for an OEM?
The HYCA-10 family description states that design customization can be discussed. Provide the mechanical envelope, conductor route, connector details, branding requirement and estimated order quantity for an engineering and quotation review.


Tel:13968747975
E-mail: bethy@heyiele.com
Add:(Zhejiang Lierde Relay Co., Ltd.) Xinguang Ind. Zone, Liushi Town, Wenzhou, Zhejiang, China